DIALux and DIALux evo are lighting design software programs that calculate illumination in a modeled room and show the result as numbers and images. You draw the space, place luminaires, and the software runs a photometric calculation to report illuminance across surfaces. DIALux evo is the newer line built around a full building model, while the classic DIALux line works from individual rooms and scenes. 

- A lighting design starts with an accurate room model, so measure the space before you open the software.
- Photometric files in IES or LDT format carry a luminaire's light distribution into the calculation.
- Illuminance values on the work plane tell you whether a layout meets its target, and the render shows how it looks.
- The tutorial workflow moves from room drawing to luminaire placement, calculation and output.
- A corner layout improves when you test furniture footprints against the light rather than the other way around.
 

## What DIALux and DIALux evo do 

DIALux lighting design software answers a practical question: how much light lands where in a room. You build a model of the space, add luminaires with known light output, and the program runs a photometric calculation over the surfaces. The output pairs a numeric report with a visual render, so a plan can be checked both by measurement and by eye. 

DIALux evo organizes the work around a building model rather than a single room. Floors, rooms and outdoor areas sit inside one project, and the calculation follows that structure. The classic DIALux line approaches the same job from room-based scenes, which suits a designer who works one space at a time. 

Neither program decides the design for you. The designer sets the room dimensions, chooses the luminaires and judges the result against a lighting target. The software supplies the arithmetic and the picture, and the judgment stays with the person holding the mouse. 

## Starting from the room you have 

The room model sets the limit on everything the software can tell you. Measure the length, width and height of the actual space, and note window positions and surface finishes. A model built from guessed dimensions produces illuminance figures that describe a room that does not exist. 

Surface reflectance matters as much as geometry. Light bounces off walls, ceiling and floor, and the calculation uses those values to estimate indirect light. A dark corner absorbs light that a pale corner reflects, so the same luminaire layout can read differently in each. 

Drawing the room first also clarifies the [furniture footprint](/articles/furniture-footprint-define-it-and-plan-with-it/). A corner with a desk, a shelf and a chair has less usable floor than an empty corner, and the lighting plan should follow the furniture you keep. Model the pieces you own, then place light around them. 

## Importing luminaires with IES and LDT files 

A luminaire import brings real light distribution data into the project. Photometric files in IES or LDT format describe how a fixture throws light in each direction, and the software uses that data instead of a generic lamp. Without the file, the calculation rests on an assumption rather than a measurement. 

Manufacturers publish photometric files for their fixtures, and you load the file that matches the exact product. Check that the file name and the luminaire description agree before you place it. A mismatched file produces a confident-looking report for the wrong product. 

The imported luminaire arrives with its own distribution curve, so two fixtures of equal power can light a room very differently. A narrow beam concentrates light on a small area, while a wide distribution spreads it across the ceiling and walls. Compare the curves rather than the wattage when you choose. 

## Running the illuminance calculation 

An illuminance calculation reports how much light falls on a chosen surface, expressed in lux. You set a work plane at the height where the task happens, such as a desk surface, and the software maps values across that plane. The map exposes dark zones and hot spots that a single average figure hides. 

Read the map as a pattern rather than one number. Areas below the target need more light or a different fixture position, and areas far above it waste energy and create glare. Moving a luminaire a short distance can reshape the pattern more than changing its output. 

Room lighting simulation extends the check beyond the work plane. Wall and ceiling values show whether the space feels bright or cave-like, and vertical illuminance matters where a person faces a surface. Judge the whole enclosure, not only the desk. 

## Reading renders and the Ansicht and luminance views 

Rendering and 3D visualization turn the calculation into an image you can discuss with a client. A photorealistic render shows color, shadow and material, which helps a person picture the finished room. The image is an interpretation of the data, so treat it as a communication tool alongside the numbers. 

The Ansicht and luminance views serve a different purpose. A luminance view maps brightness as the eye perceives it, which reveals glare sources that an illuminance map can miss. A bright fixture in the field of view may score well on the work plane while still causing discomfort. 

Use the views together. The render answers how the room looks, the illuminance map answers whether the task is lit, and the luminance view answers whether anything in sight is too bright. Each view covers a gap the other two leave. 

## A tutorial workflow from model to report 

A DIALux evo lighting design tutorial follows a sequence that keeps the project honest. Draw the room to measured dimensions, set the surface reflectance, and define the work plane before any luminaire appears. The order matters because later steps inherit the values you set early. 

Next, import the luminaires you intend to use and place them in the model. Run the photometric calculation, then read the illuminance map against your target. Adjust position, quantity or fixture type, and run the calculation again until the pattern is even and the values fit. 

Finish with the visual output. Produce the render for the client conversation and keep the luminance view for your own glare check. Save the project with the luminaire files attached, so a later revision starts from the same data. 

- Measure the room and enter true dimensions and heights.
- Set wall, ceiling and floor reflectance values.
- Define the work plane at task height.
- Import IES or LDT files for each luminaire.
- Place luminaires and run the calculation.
- Read the illuminance map and adjust the layout.
- Produce the render and check the luminance view.
 

## Modeling a corner that works with the light 

A photometric corner model should follow the layout you actually want to keep. Place the furniture first, then test whether the light reaches the surfaces people use. A reading chair needs light on the page, and a shelf needs light on the spines, so each piece sets its own requirement. 

Compare furniture footprints inside the same room model. Move the desk, the lamp and the chair in turn, and rerun the calculation after each change. The software lets you test a layout without buying anything, and the comparison shows which arrangement leaves the fewest dark patches. 

Corner lighting often needs two sources rather than one. A ceiling fixture lights the floor, while a task lamp lights the work surface, and the pair covers what either alone would miss. Model both and read the combined map before you settle on a position. 
| Corner element | What to model | What to check | 
| Desk | True footprint and height | Illuminance on the work surface | 
| Task lamp | IES file for the fixture | Glare in the seated view | 
| Shelf | Depth and shelf spacing | Vertical light on the spines | 
| Chair | Position and clearance | Shadow cast on the desk |  

## Limits of the software and where a specialist helps 

DIALux and DIALux evo lighting design software models light, not electrical safety. The programs do not verify wiring, circuit capacity or the suitability of a fixture for a damp location. Those questions belong to a qualified electrician or engineer, and a lighting plan should not be read as an electrical approval. 

The calculation is only as good as its inputs. A generic luminaire file, a guessed reflectance or a wrong room height all shift the result, and the report will not warn you. Check each input against a real measurement or a manufacturer document before you trust the output. 

Complex spaces with daylight, curved surfaces or unusual materials may exceed what a simple model captures. Daylight simulation in particular depends on climate data and window details that need careful setup. Where the design carries risk, bring in a lighting specialist to review the model and the assumptions behind it. 

## Questions about DIALux lighting design 

### Is DIALux evo the same as DIALux? 

No, DIALux evo and classic DIALux are separate lines from the same developer. DIALux evo builds the project as a full building model with floors and rooms, while classic DIALux works from individual room scenes. The photometric calculation sits at the core of both. 

### What file format do luminaires need for DIALux? 

Luminaires enter DIALux and DIALux evo through photometric files in IES or LDT format. These files carry the light distribution of a specific fixture, so the calculation reflects the real product. Load the file that matches the exact luminaire you plan to use. 

### Can I follow a DIALux evo lighting design tutorial as a beginner? 

Yes, a beginner can follow a DIALux evo lighting design tutorial if it starts with the room model. Draw the measured space, set the surface reflectance and define the work plane before placing luminaires. Those first steps carry more weight than any later setting. 

### What does an illuminance calculation tell me about a room? 

An illuminance calculation reports how much light reaches a chosen surface, in lux, across a mapped area. The map shows dark zones and hot spots rather than one average figure. Compare the values against the target for the task in that space. 

### Why do I need the luminance view as well as a render? 

A render shows how the room looks, while a luminance view shows brightness as the eye receives it. The luminance view exposes glare sources that an illuminance map can miss. Both views check different problems, so use them together. 

### Can the software confirm my wiring is safe? 

No, DIALux and DIALux evo do not check wiring, circuit capacity or fixture suitability for damp locations. The software handles photometric calculation only. Have a qualified electrician or engineer review the electrical side of the plan.